Станьте экспертом по контролю жидкости первого класса высокого давления в мире

Suncenter  >  AI - Page Sitemap  >  Suncenter stable oxygen pump factory price for refrigeration industry
Suncenter stable oxygen pump factory price for refrigeration industry

Suncenter stable oxygen pump factory price for refrigeration industry

MOQ
1 Set
Название бренда
SUNCENTER
Сертификат
ISO/CE/SGS
Гарантия
13 Months
Упаковка
By Plywood case
Порт доставки
Shenzhen/Hongkong
Оплата
T/T,Western Union,Credit card.
Метод транзакции
EXW,FOB,DDP,CIF,CFR
Место происхождения
Guangdong Province, China (Mainland)
Срок поставки
Within 10-15 working days after received deposit
Цена
latest_price
latest_price_title
quantity_needed:
pieces
Электронной почты:

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter stable oxygen pump factory price for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter stable oxygen pump factory price for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter stable oxygen pump factory price for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter stable oxygen pump factory price for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter stable oxygen pump factory price for refrigeration industry-5
Suncenter stable oxygen pump factory price for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





liquid refrigerant pump is equipped with a high-quality compressor. It is compact in structure and easy in installation. Moreover, the optimized plumbing makes it low in noise during operation.
oxygen pump is processed by noise reduction technology. It causes low noise during operation. Moreover, it is of reasonable and simple design and is easy to operate and maintain.
oxygen pump is scientific in design, simple in structure, low in noise and easy in maintenance.
liquid refrigerant pump is equipped with a high-quality compressor and is processed based on noise reduction technology. It is of stable performance, high efficiency and low noise, and is very popular among customers.
liquid refrigerant pump is processed by vibration reduction and noise reduction technology. It is stable in operation and low in noise. Moreover, it has a beautiful appearance, smooth lines, and a unique structure.
We insist on using cost-effective raw materials and using automated machinery and equipment to produce liquid refrigerant pump, which effectively reduces the cost of raw materials, labor costs and processing costs, and promotes the wholesale price of liquid refrigerant pump to be at a relatively low level in the industry.
Сообщение о продукте
Онлайн чат 编辑模式下无法使用
Оставьте свое сообщение inputting