Станьте первоклассным экспертом по управлению жидкостями высокого давления в мире

Suncenter  >  AI - Page Sitemap  >  Suncenter refrigerant refrigerant pump at discount for refrigeration industry
Suncenter refrigerant refrigerant pump at discount for refrigeration industry

Suncenter refrigerant refrigerant pump at discount for refrigeration industry

MOQ
1 Set
Название бренда
SUNCENTER
Сертификат
ISO/CE/SGS
Гарантия
13 Months
Упаковка
By Plywood case
Порт доставки
Shenzhen/Hongkong
Оплата
T/T,Western Union,Credit card.
Метод транзакции
EXW,FOB,DDP,CIF,CFR
Место происхождения
Guangdong Province, China (Mainland)
Срок поставки
Within 10-15 working days after received deposit
Цена
latest_price
latest_price_title
quantity_needed:
pieces
Электронной почты:

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter refrigerant refrigerant pump at discount for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter refrigerant refrigerant pump at discount for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter refrigerant refrigerant pump at discount for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter refrigerant refrigerant pump at discount for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter refrigerant refrigerant pump at discount for refrigeration industry-5
Suncenter refrigerant refrigerant pump at discount for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





Suncenter manual oxygen pump combines the advantages of a conventional process and modern production. It can be configured in a straight line or in an L-shaped configuration
Suncenter manual oxygen pump leaves a lasting impression on the industry with the unique and innovative design. Equipped with a safety system, the product can detect the faults
The deviation of Suncenter manual oxygen pump is spotted through ongoing quality control techniques. The product is widely used for commercial applications
Suncenter manual oxygen pump can be exclusively designed and manufactured according to consumers' specific requirement. The product is hygiene with no bacteria or mold built up
Suncenter refrigerant pump is designed & manufactured by using top-quality material and advanced tools & equipment in conformity with the industry standards. The product features excellent torque accuracy
The product has reliable working performance. It is able to withstand impact and high loading working conditions without sacrificing its efficiency. The product features a high degree of automation
Сообщение о продукте
Онлайн чат 编辑模式下无法使用
Оставьте свое сообщение inputting