Станьте экспертом по контролю жидкости первого класса высокого давления в мире

Suncenter  >  AI - Page Sitemap  >  Suncenter pressure hydrostatic pressure test type for safety valve calibration
Suncenter pressure hydrostatic pressure test type for safety valve calibration

Suncenter pressure hydrostatic pressure test type for safety valve calibration

MOQ
1 Set
Название бренда
SUNCENTER
Сертификат
ISO/CE/SGS
Гарантия
13 Months
Упаковка
By Plywood case
Порт доставки
Shenzhen/Hongkong
Оплата
T/T,Western Union,Credit card.
Метод транзакции
EXW,FOB,DDP,CIF,CFR
Место происхождения
Guangdong Province, China (Mainland)
Срок поставки
Within 10-15 working days after received deposit
Цена
latest_price
latest_price_title
quantity_needed:
pieces
Электронной почты:
Company Advantages
1. Suncenter natural gas pressure booster undergoes a series of tests. These tests are aimed to testify its abrasion resistance, impact resistance, scratch resistance, chemical resistance, etc. It has a small volume and a simple structure
2. The product, with great commercial value, has a promising market application prospect. Its output pressure can be easily adjustable
3. This product has good colorfastness. After long use and many washes, the fabric retained its original color. It is automated with many modification and control options available

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter pressure hydrostatic pressure test type for safety valve calibration-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter pressure hydrostatic pressure test type for safety valve calibration-2



The hottest selling- model A and model C cabinet picture


Suncenter pressure hydrostatic pressure test type for safety valve calibration-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter pressure hydrostatic pressure test type for safety valve calibration-4



Suncenter pressure hydrostatic pressure test type for safety valve calibration-5
  • DGS series gas boosters working pictures


Suncenter pressure hydrostatic pressure test type for safety valve calibration-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter pressure hydrostatic pressure test type for safety valve calibration-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is world-renowned for the rich knowhow on manufacturing hydrostatic pressure test . One of our biggest strengths for our pressure booster pump lies in its high-end technology.
2. Drawing upon the advanced technology, Suncenter are the main force in hydraulic test bench market.
3. High durability performance of gas booster compressor makes our clients rest assured during the transportation. We will continue to practice the win-win promise, hand in hand with partners to keep good and long cooperation. We will work closely with clients to provide faster response, more comprehensive service and technical support.
The on-site construction process of Suncenter hydrostatic pressure test is conducted by skilled, experienced installing professionals who bring years of industry experience to each project. Aluminum materials help it reduce maintenance costs
Suncenter pressure booster pump is produced under standardized and scientific lighting standards. For example, the selection process of the light source highly meet the international lighting standards. Its weight-lifting capacity depends on the client’s needs
Suncenter pressure booster pump goes through a series of sophisticated workmanship. The comminution and concentration of raw materials are carried out to provide a more concentrated material for the procedures of extractive metallurgy. It is designed to offer maximum capacity in strength for daily basis usage
Suncenter pressure booster pump meets the regulatory requirements of the textile market. The textile fibers, dyestuff, and different kinds of agents used in it are guaranteed to meet the standards. Its metal parts are electropolished for being robust and corrosion-resistant
The manufacturing of Suncenter hydrostatic pressure test is carried out through the following processes: metal materials preparation, turning, milling, boring, welding, marking, and assembling. It will provide durable and cost-efficient operation for decades
The product can light up instantly. Its high-intensity illuminating elements can not only withstand the impact of instantaneous current but also enter the normal working state for the first time. It is suitable for a small obscure helipad, regional airport or international hub
Сообщение о продукте
Онлайн чат 编辑模式下无法使用
Оставьте свое сообщение inputting