Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter fire extinguisher refill for fire extinguisher
Suncenter fire extinguisher refill for fire extinguisher

Suncenter fire extinguisher refill for fire extinguisher

MOQ
1 Set
Название бренда
SUNCENTER
Сертификат
ISO/CE/SGS
Гарантия
13 Months
Упаковка
By Plywood case
Порт доставки
Shenzhen/Hongkong
Оплата
T/T,Western Union,Credit card.
Метод транзакции
EXW,FOB,DDP,CIF,CFR
Место происхождения
Guangdong Province, China (Mainland)
Срок поставки
Within 10-15 working days after received deposit
Цена
latest_price
latest_price_title
quantity_needed:
pieces
Электронной почты:
Company Advantages
1. Suncenter fire extinguisher refill is the outcome of thermodynamics knowledge. Its whole body part especially the air circulation parts are made with special materials and circulating layout. The product can be mounted in any position
2. This product is very popular in the market and is widely used in the market. The product has reliable performance and simple access to the operation
3. This product has not only insulating, moisture absorbing and temperature compensating effects, but also the ability to adapt to body temperature. It has the capability of ultimate pressure, flow output horsepower
4. This product is anti-wrinkle. The twist of the yarn is professionally treated to an appropriate level to enhance the stretchability and elasticity of the yarn. The speed of this product is infinitely variable
5. The product has reliable working performance. It is able to withstand impact and high loading working conditions without sacrificing its efficiency. The speed of this product can be adjusted steplessly

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter fire extinguisher refill for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter fire extinguisher refill for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter fire extinguisher refill for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter fire extinguisher refill for fire extinguisher-4
Suncenter fire extinguisher refill for fire extinguisher-5


video





Company Features
1. Having been applying ourselves into the production of fire extinguisher refill, Suncenter aims to be the leading manufacturer. The R&D team in Dongguan Suncenter Fluid Control Equipment Co., Ltd is professional and experienced.
2. The fire extinguisher refill station is made by fire extinguisher filling equipment technology.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd has the advanced equipment and technology needed for automatic filling machine . Suncenter always holds onto the aim of being a fire extinguisher refill manufacturer. Please contact.
Suncenter fire extinguisher refill is designed according to the needs of customers. It provides excellent lubricating oil retention
Suncenter fire extinguisher refill is available in diverse attractive design styles. It is available in standard and heavy duty versions
Suncenter fire extinguisher filling equipment offers various design styles to global customers. It ensures no cracks, notches, or holes on its surface
Suncenter fire extinguisher filling equipment is manufactured under standardized production conditions. Without sharp edges, this product is safe to use
Suncenter automatic filling machine is designed by our most brilliant and talented professionals with the use of best quality materials and advanced production tools. It is less prone to crack and deform
The quality of this product is guaranteed to withstand a variety of rigorous tests. It is inspected and approved for dimensional compliance
Сообщение о продукте
Онлайн чат 编辑模式下无法使用
Оставьте свое сообщение inputting