Станьте экспертом по контролю жидкости первого класса высокого давления в мире

Suncenter  >  AI - Page Sitemap  >  safe pressure booster pump test type for safety valve calibration
safe pressure booster pump test type for safety valve calibration

Safe pressure booster pump test type for safety valve calibration

MOQ
1 Set
Название бренда
SUNCENTER
Сертификат
ISO/CE/SGS
Гарантия
13 Months
Упаковка
By Plywood case
Порт доставки
Shenzhen/Hongkong
Оплата
T/T,Western Union,Credit card.
Метод транзакции
EXW,FOB,DDP,CIF,CFR
Место происхождения
Guangdong Province, China (Mainland)
Срок поставки
Within 10-15 working days after received deposit
Цена
latest_price
latest_price_title
quantity_needed:
pieces
Электронной почты:
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has more advantages over similar products in terms of technology and quality.
Product Details
With the dedication to pursue excellence, Suncenter Fluid Control Equipment strives for perfection in every detail.
Company Advantages
1. Suncenter hydraulic pump test bench is entirely made of high quality raw materials with safety.
2. The product is stable in powering. It can absorb the energy-intensive sunlight, ambient light, and some artificial light before converting the energy into electricity.
3. The product has an excellent and precise filtration effect. The reverse osmosis technique only allows the hydrone and dissolved oxygen to get through and excludes out sands, pesticide, bacteria, and heavy metals.
4. This product has many advantages and huge economic benefits, and has gradually developed into a trend in the industry.

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


safe pressure booster pump test type for safety valve calibration-1


DGS booster system = booster pump+ following valves, gages, and parts


safe pressure booster pump test type for safety valve calibration-2



The hottest selling- model A and model C cabinet picture


safe pressure booster pump test type for safety valve calibration-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


safe pressure booster pump test type for safety valve calibration-4



safe pressure booster pump test type for safety valve calibration-5
  • DGS series gas boosters working pictures


safe pressure booster pump test type for safety valve calibration-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

safe pressure booster pump test type for safety valve calibration-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is one of the most dependable manufacturers of hydraulic pump test bench and has been highly appraised for its extensive expertise in designing and manufacturing.
2. We have an excellent customer service team. They have deep customer insight. They understand how to help clients make the right choice, what clients actually need, and how to get closer to customers.
3. While Dongguan Suncenter Fluid Control Equipment Co., Ltd is striving to become the world's leading pressure booster pump supplier, we are able to do our best. Welcome to visit our factory! Our business principle is 'perform the contract and meet the commitments.' Welcome to visit our factory! Customer demand is the driving force for Suncenter development. Welcome to visit our factory! Suncenter Fluid Control Equipment works hard for the best interests of our customers. Welcome to visit our factory!
Suncenter pressure booster pump is exclusively developed by our R&D team who is exploring new raw materials without limits and experimenting with new combinations of ingredients. This product has the characteristics of explosion proof
Suncenter pressure booster pump will be tested to meet the quality standards required in the seal accessories industry, including its hardness, airtightness, lubrication capacity, etc. The product combines principles of simple operation with rugged construction
The manufacture of Suncenter hydraulic pump test bench is eco-friendly. An optimal composition of the fuels is used in the production process so as to sustainably reduce the proportion of emissions. Its operation is safe with no heat, flame or spark risk
The production process of Suncenter pressure booster pump is strictly controlled to meet special requirements in terms of shape, temperature, dimensional accuracy, weight, and stability. Its operation is safe with no heat, flame or spark risk
The touch screen of Suncenter hydraulic pump test bench is exclusively developed by in-house R&D members to accommodate various business requirements. The team aims to develop a user-friendly monitor. The speed of this product can be adjusted steplessly
As our QC experts strictly control the quality throughout the whole production process, the quality of the product can be fully guaranteed. It has a small volume and a simple structure
Сообщение о продукте
Онлайн чат 编辑模式下无法使用
Оставьте свое сообщение inputting